Chemical Resistant Concrete Coating

CHEMICAL RESISTANT, SINGLE COMPONENT URETHANE


Moisture Cure Urethanes are the ultimate in high-performance concrete floor coatings. They are 100% UV stable, extremely durable, wear, abrasion and chemical resistant. Moisture Cure Urethanes are ready to use, single component coatings that require no mixing before use.

PolyRez Moisture Cure Urethane is available in two different formulas.

MCU-85 is a very low odor, 85% solids moisture cure urethane sealer, perfect for use as a final top-coat on all types of residential, commercial and industrial floors. MCU-85 is the perfect final top-coat when the ultimate in durability and chemical resistance is required. It also offers user friendly installation since it has very low odor.

MCU-55 is a lower solids version with 55% solids. This lower solids version produces a slightly thinner film than the 85% version when applied at the same rate. MCU-55 also has a much stronger odor than the 85% version, but the additional solvent often aids in application and penetration. MCU-55 is also an excellent final top-coat for all types of residential, commercial and industrial floors, also offering the ultimate in durability and chemical resistance.

Although MCU-55 is typically only recommended as a final top coat over PolyRez Epoxies, Polyaspartics and Urethanes, in specific situations, MCU-55 may also be used directly to properly prepared concrete floors. In this application, the utmost care must be taken to be sure the concrete is COMPLETELY DRY and the slab contains NO MOISTURE before application. Any excess moisture will cause the coating to instantly harden and cure before it can penetrate or bond to the surface.

 

MCU is the perfect final top coat for all types of high-performance floors:

Stained Floors
Acid Resistant Stained Floor
Flake Floors
Most Durable Flake Garage Floor
"Epoxy" Floors
Industrial Floor Coating
Quartz Floors
Hardest Concrete Coating

 

Essentials

  • Ultra-High Performance
  • Use As Final Top-Coat
  • For Interior and Garage Floors
  • 1k Moisture Cure Urethane
  • High-Gloss Finish
  • Roller Application
  • Coverage - See Detailed Info Below

 

MCU-85 Tech Data Sheet

MCU-85 Safety Data Sheet

 

MCU-55 Tech Data Sheet

MCU-55 Safety Data Sheet

 

CA WarningWARNING: The MCU-55 version of this product can expose you to chemicals including Cumene, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov.

CA WarningWARNING: The MCU-85 version of this product can expose you to chemicals including Methanol and Hydrogen Cyanide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Due to VOC regulations the 55% solids version of this product CANNOT be shipped to Colorado, Connecticut, Delaware, Maryland, New York, Ohio, Rhode Island, Northwest Utah* or the SCAQMD, CARB-2007 and CARB-2020 regions of California*. If you are in these areas please do not try to order the 55% version of this product. We WILL NOT be able to process your order!!

* See VOC MAP for specific regulated areas.

 


Detailed Info!

To learn more, keep reading or click a link below to jump to a specific topic:

 


Cleaning and Preparation Instructions

Polyrez MCU is designed to be a CLEAR, final, top coat only. If possible, recoat within the suggested recoat window of the previous coating. If recoating outside the suggested recoat window of the previous coating or beyond 24 hours, sand using a 80-120 grit sanding screen to ensure adequate adhesion between coats. Vacuum dust thoroughly, rinse with clean water and remove excess water with a wet/dry vacuum or floor scrubber. Allow surface to dry completely prior to application of coating. Where applicable and with adequate ventilation, wipe the surface with acetone and a . CAUTION: Acetone is extremely flammable! If using acetone follow all safety precautions, make sure no pilot lights, open flames, sources of static electricity, sparks or extreme heat sources are present. Use recommended personal protection for acetone.

 

Application Instructions

APPLICATION OVER SMOOTH EXISTING COATING - Apply using a 1/4” mohair blend roller, dip and roll the mixed material from a roller pan. 18” rollers are recommended for any surface to speed up application time and reduce roller marks. Start by placing the wet roller at one corner of an approximate 4’ x 4‘ square and roll the material at an angle to opposite corner applying no pressure to the roller. Spread the material across only that square and immediately back roll to even out material and roller lines. Adjust the size of your square as needed based on the amount of material being applied with the roller. After finishing the square, move on to the next square using the same technique. While applying keep a wet edge to prevent roller marks. It is recommended to work in sections usually using control joints as dividers to ensure proper application results. Discard any material left in the roller pan when coating is complete. Do not allow to puddle! Use a brush to remove excess coating in joints.

APPLICATION OVER CHIP SYSTEM SURFACES (MCU-85 ONLY) - MCU 85 may be used directly over flakes as a final top coat. Apply MCU 85 by pouring directly over flake and spreading evenly with a flat, flexible squeegee and back roll using our 3/8” nap, shed-free, . Always fill the roller cover in a puddle before beginning to back roll. Apply evenly at a rate of 175 - 225 square feet per gallon, always keeping a wet edge. Do not allow to puddle. Use a brush to remove excess coating in joints.

Do not apply MCU if surface temperature is below 50° F., or above 80° F.

See TDS for recommended cure times and re-coat window information.

CAUTION: Moisture cured urethane cures by absorbing moisture from the atmosphere and then hardening. If the container is open for any period of time or brushes or rollers are dipped in and out, then the contents are likely to cure and become solid. Partially filled containers are also likely to cure and become solid over a period of time. Pour out only what will be used up in the immediate time frame and reseal the original container each time after pouring product out. Discard any material left in the roller pan when coating is complete. Left over material should be poured into air tight, metal cans that have little to no air space in them with the lid securely in place. Always test a small area for compatibility before proceeding.

SLIP RESISTANCE: may be used for additional slip resistance. Follow mixing instructions and do not overload system. All non-skid additives may shorten the life of the film to some degree.

CLEAN UP: Clean up tools with MEK or Acetone.

 

Of course, having the right tools will make your job easier, so scroll to the bottom to see our recommended Rollers, Brushes and Application Tools!

 

Coverage Rates

Coverage rates are approximate and will vary depending on substrate density, porosity, texture and application method. In most cases, only one coat is recommended. Excessive build-up should be avoided.

MCU-55
Over Existing Coating : 250 - 350 ft² per gallon

MCU-85
Over Existing Coating : 300 - 350 ft² per gallon
Over Media Broadcast Systems : 175 - 225 ft² per gallon

 

Maintenance

Once properly applied, surfaces coated with MCU will require very little maintenance. The surface may periodically require a light cleaning to remove dirt, dust, mud, etc. In most cases, simple mopping or autoscrubbing is all that is needed for routine cleaning. may also be used for additional protection and slip-resistance as it meets requirements for ASTM D2047.

 

FAQ's

 

Shipping Restrictions Warning

The 55% solids version of this product CANNOT be shipped to Colorado, Connecticut, Delaware, Maryland, New York, Ohio, Rhode Island, Northwest Utah* or the SCAQMD, CARB-2007 and CARB-2020 regions of California*. If you are in these areas please do not try to order the 55% version of this product. We WILL NOT be able to process your order!!

* See VOC MAP for specific regulated areas.

Got Questions?

Check out the "Help Center", send us an email or just give us a call and we'll be glad to help you with your order!

Extra Information

Brand:
Surfkoat
"Wet Look" Color Enhancement?:
Yes
VOC Compliance:
LADCO (IL,IN)
VOC Compliance:
OTC-Phase-1 (DC,MA,ME,NH,NJ,PA,VA)
VOC Compliance:
OTC-Phase-2 (CT,DE,MD,MI,NY,OH,RI)
VOC Compliance:
Colorado
VOC Compliance:
NW Utah
VOC Compliance:
Maricopa AZ
VOC Compliance:
CARB-2002
VOC Compliance:
CARB-2007
VOC Compliance:
CARB-2020
VOC Compliance:
SCAQMD

Additional Resources

Shop by Brand

Bakers
Surfkoat
F9
Diamabrush
Chapin
Swissmex
Polyrez
Malish
TeeJet
F9
Homax
Spraying Systems Co